Five published notebooks under the GnaniNet name. All five were rerun on Kaggle on October 14, 2026. Accuracy, prediction counts, parameter counts, and reported macro F1 scores matched the earlier results. These runs evaluate saved weights through compiled C inference from Python; they do not retrain the models.
Download results & provenanceMeasured outputs, with a source behind each number.
These five benchmark metrics come from fresh Kaggle runs, with execution logs retrieved through the Kaggle CLI. The published notebooks load model weights, run inference on test samples, and compute their results. Follow each result to its public notebook, task dataset, and saved weights to inspect the procedure and recorded output or rerun it on Kaggle.
“Evaluated on Kaggle” identifies where the code ran. It does not mean Kaggle independently audited the training data, model selection, baseline comparisons, or suitability for a real-world deployment.
What the measurements establish.
Each result belongs to a particular model, dataset, and split. Compact weights are useful evidence; they do not by themselves establish lower total memory, energy use, or better accuracy than another model.
EEG eye state2,820 / 2,995 correct; 1,576 parameters; 6,304 bytes of float32 weights.
80/20 stratified split, seed 42. Measured inference-loop time: 14.9 µs per sample in the October 14 Kaggle run, including Python overhead.
Smartphone activity2,796 / 2,947 correct; 15,416 parameters; macro F1 0.9485.
The notebook uses the dataset’s official subject-independent train/test split.
ECG heartbeat21,257 / 21,892 correct; 97.10% accuracy; macro F1 0.8390.
The macro F1 adds context that overall accuracy alone misses. Uses the supplied train/test split.
EEG emotions421 / 425 correct; 163,788 parameters; recorded accuracy 99.06%.
The local export script selects the best of five seeds using test accuracy. Its exact lineage to the published weights remains unverified; the rerun reproduces inference but does not establish an untouched holdout estimate.
Seizure recognition2,229 / 2,300 correct; 12,072 parameters; recorded accuracy 96.91%.
80/20 split, seed 42. This classification benchmark does not establish clinical performance.
Notebook baseline tables are authored comparisons, not baselines rerun under matched conditions. No global ranking, C-versus-NumPy speedup, or drone / microcontroller performance is established by these runs.
The separate fraud demo above uses the local 1,059-parameter model. Its repository-reported 91.6% accuracy is not one of these five Kaggle results.